Skip to content
Book on WhatsApp

P2D63

Battery Charging System Negative Contactor C Stuck Closed

The negative contactor C of the battery charging system reports a stuck closed condition. HV charging path cannot be commanded reliably.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: hard

Common causes

Ordered by how often each turns out to be the cause.

  • Contactor contacts welded closedCommon
  • Output driver stuck onPossible
  • Carbon or debris buildup preventing free movementLess likely

Parts involved

  • Bcs Neg Contactor C
  • Wiring Harness
  • Bms

P2D63 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.