Skip to content
Book on WhatsApp

P2C92

Hybrid/EV Battery Contactor Control Supply Circuit/Open

The supply circuit for the hybrid battery contactor control reports a open condition. Contactor coils may not energise as expected.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: medium

Symptoms

  • EV/hybrid system warning light on
  • Reduced power output or limp mode
  • Charging may fail or be slowed
  • Reduced electric range

Common causes

Ordered by how often each turns out to be the cause.

  • Open in supply wireCommon
  • Supply fuse blownPossible
  • Pin pushed back out of connector bodyLess likely

Parts involved

  • Hybrid Battery Contactor Control Supply
  • Wiring Harness
  • Bms

P2C92 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.