Fuel Shutoff Valve A Control Circuit Performance/Stuck Off

The first fuel shutoff valve is commanded on but does not open. Fuel cannot reach the engine via this path.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: medium

Common causes

Ordered by how often each turns out to be the cause.

  • Valve seized closed by debrisCommon
  • Solenoid loses force from coil agingPossible
  • Carbon or debris buildup preventing free movementLess likely

Parts involved

  • Fuel Shutoff Valve A
  • Solenoid

P26B3 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.