Skip to content
Book on WhatsApp

P2675

Air Cleaner Inlet Control Circuit / Open

The controller cannot drive the air cleaner inlet control valve (warm-air or snorkel switching for cold-start emissions). Stuck in default position so cold-start fueling is sub-optimal.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: easy

Common causes

Ordered by how often each turns out to be the cause.

  • Open coil in inlet valve solenoidCommon
  • Broken control wirePossible

Parts involved

  • Air Cleaner Inlet Valve
  • Solenoid
  • Wiring Harness

P2675 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.