P265E

B Rocker Arm Actuator Position Sensor Circuit Intermittent/Erratic Bank 1

The position sensor signal for actuator B on bank 1 jumps or drops out intermittently. Usually a loose connector or a chafed wire.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: medium

Common causes

Ordered by how often each turns out to be the cause.

  • Sensor connector not fully seatedCommon
  • Harness chafed against valve coverPossible
  • Connector with intermittent contact under vibrationLess likely

Parts involved

  • Rocker Arm Position Sensor B B1
  • Wiring Harness