Skip to content
Book on WhatsApp

P25B6

Turbocharger/Supercharger Wastegate B Stuck Closed

Same as wastegate A stuck closed, applied to the second wastegate. Boost control tracks commanded vs. actual manifold pressure; persistent deviation means wastegate, vanes, hose or actuator are not delivering the requested pressure.

  • Check engine light: Yes
  • Emissions related: Yes
  • Repair difficulty: hard

Symptoms

  • Check engine light on
  • Significant power loss / limp mode
  • Possible blue or black smoke from exhaust
  • Whistling or hissing sound from intake

Common causes

Ordered by how often each turns out to be the cause.

  • Carbon-locked wastegate flapCommon
  • Carbon or debris buildup preventing free movementLess likely
  • Component wear with age - mechanical playLess likely

Parts involved

  • Wastegate B
  • Turbocharger B

P25B6 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.