Skip to content
Book on WhatsApp

P2512

Event Data Recorder Request Circuit/Open

The Event Data Recorder (EDR / black box) request line — used by the ECM or restraint module to trigger the EDR to capture pre-crash data — is open. The ECM cannot trigger an event capture, so any subsequent crash event would not be recorded reliably.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: medium

Common causes

Ordered by how often each turns out to be the cause.

  • Open request wire or unplugged moduleCommon
  • Failed input stage in the EDRPossible
  • Pin pushed back out of connector bodyLess likely

Parts involved

  • Event Data Recorder
  • Request Wire

P2512 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.