Closed Loop Reductant Injection Control At Limit Flow Too High

Same as P249D with the controller fully closing the dosing valve yet still measuring more flow than needed - the valve does not seat fully.

  • Check engine light: Yes
  • Emissions related: Yes
  • Repair difficulty: medium

Symptoms

  • Check engine light or NOx warning on
  • AdBlue/DEF level or quality warning
  • Possible no-start countdown after ignore period
  • Failed emissions inspection (NOx)

Common causes

Ordered by how often each turns out to be the cause.

  • Dosing valve does not seat fullyCommon

Parts involved

  • Reductant Injector

P249E is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.