Skip to content
Book on WhatsApp

P243C

Particulate Filter Regeneration Frequency Bank 2

The DPF on bank 2 needs regeneration more often than calibrated. Possible causes are an oil-burning engine, fuel-injector leak, short-trip operation, or a sensor offset.

  • Check engine light: Yes
  • Emissions related: Yes
  • Repair difficulty: medium

Symptoms

  • Check engine light or DPF warning light on
  • Power loss / limp mode
  • Increased fuel consumption
  • Failed forced regeneration attempts

Common causes

Ordered by how often each turns out to be the cause.

  • Short-trip operationCommon

Parts involved

  • DPF B2
  • Fuel Injectors