Skip to content
Book on WhatsApp

P23B3

NOx Sensor Heater Control Circuit High Bank 1 Sensor 3

Same as P23B1 with the heater control line shorted to supply. The sensor heater warms the element to operating temperature (~600 °C); without it the lambda sensor stays inactive in closed loop and the ECM cannot trim mixture.

  • Check engine light: Yes
  • Emissions related: Yes
  • Repair difficulty: medium

Symptoms

  • Check engine light or NOx warning on
  • AdBlue/DEF level or quality warning
  • Possible no-start countdown after ignore period
  • Failed emissions inspection (NOx)

Common causes

Ordered by how often each turns out to be the cause.

  • Heater control line shorted to supplyCommon
  • Connector pins corroded - high contact resistanceLess likely
  • Supply wire pinched against B+ sourceLess likely

Parts involved

  • NOX Sensor B1s3 Heater

P23B3 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.