Hybrid/EV Battery Pack Cell Voltage High

The BMS detects at least one cell with voltage above the safe upper limit. Risk of cell damage from overcharge.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: hard

Symptoms

  • EV/hybrid system warning light on
  • Reduced power output or limp mode
  • Charging may fail or be slowed
  • Reduced electric range

Common causes

Ordered by how often each turns out to be the cause.

  • Cell balancing failed - cell overchargedCommon
  • Cell with reduced capacity reaches voltage limit earlyPossible
  • Pack cell imbalance approaching service thresholdLess likely