Skip to content
Book on WhatsApp

P0AE2

Hybrid/EV Battery Precharge Contactor Circuit Stuck Closed

The HV battery precharge contactor is stuck in the closed position. Risk of damage to precharge resistor from sustained current.

  • Check engine light: Yes
  • Emissions related: No
  • Repair difficulty: hard

Symptoms

  • EV/hybrid system warning light on
  • Reduced power output or limp mode
  • Charging may fail or be slowed
  • Reduced electric range

Common causes

Ordered by how often each turns out to be the cause.

  • Contacts welded closedCommon
  • Driver stuck onPossible
  • Carbon or debris buildup preventing free movementLess likely

Parts involved

  • Hv Battery Precharge Contactor
  • Precharge Resistor

P0AE2 is a generic OBD-II code defined by SAE J2012. Exact wording and diagnostic procedure vary by manufacturer and model. Code definitions are drawn from the public-domain OBDex dataset; the workshop notes are our own.