P045D
EGR B Control Circuit High
EGR B drive line stuck high — short to B+. EGR mixes inert exhaust into intake to lower combustion peak temperature — too little raises NOx, too much causes misfires and rough running.
- Check engine light: Yes
- Emissions related: Yes
- Repair difficulty: medium
Symptoms
- Check engine light on
- Pinging or knocking under load
- Power loss and hesitation
- Possible rough idle
- Failed emissions inspection (NOx)
Common causes
Ordered by how often each turns out to be the cause.
- Short to B+Common
- Connector pins corroded - high contact resistanceLess likely
- Supply wire pinched against B+ sourceLess likely
Parts involved
- EGR Valve